Validation of computer morphs for grading contact lens complications

Efron, Nathan, Morgan, Philip B., & Jagpal, Ritu (2002) Validation of computer morphs for grading contact lens complications. Ophthalmic and Physiological Optics, 22(4), pp. 341-349.

View at publisher

Abstract

Abstract An alternative to the use of printed grading scales for assessing the severity of contact lens-induced ocular pathology is to use computer-generated grading morphs. This technique involves manipulation of a continuously variable movie sequence until this matches the severity of the condition being observed. To validate the use of computer morphs, nine experienced optometrists were each invited to grade - to the nearest 0.1 increment - an image of each of 16 contact lens complications, using printed scales (Efron Grading Scales for Contact Lens Complications) and computer morphs (Efron Grading Morphs). This entire procedure was repeated approximately 2 weeks later, yielding a total data base comprising of 576 individual grading estimates. Good accuracy was achieved using computer morphs, as evidenced by the similarity between the mean of the test and retest grading estimates for the printed scales (2.8 +/- 0.7) and the computer morphs (2.6 +/- 0.8) (F1,8 = 2.7, p = 0.14). There was no difference in median reliability between the printed scales (+/- 0.41) and the computer morphs (+/- 0.43) (Z = 0.1, p = 0.95). Computer morphs are thus considered to have been validated in view of their accuracy and reliability compared with printed scales. In addition, computer morphs offer considerable utility in terms of computer-based clinical record keeping, teaching and learning, and clinical research.

Impact and interest:

14 citations in Scopus
Search Google Scholar™
14 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 11012
Item Type: Journal Article
Refereed: Yes
Additional Information: For more information, please refer to the journal’s website (see hypertext link) or contact the author.
Keywords: accuracy, computer grading morphs, contact lens complications, grading tools, printed grading scales, reliability, validation
DOI: 10.1046/j.1475-1313.2002.00049.x
ISSN: 0275-5408
Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300)
Divisions: Current > Research Centres > Centre for Health Research
Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2002 Blackwell Publishing
Copyright Statement: The definitive version is available at www.blackwell-synergy.com
Deposited On: 28 Nov 2007 00:00
Last Modified: 10 Aug 2011 16:16

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page