QUT ePrints

Visual performance after overnight orthokeratology

Johnson, Kate L., Carney, Leo G., Mountford, John A., Collins, Michael J., Cluff, Scott, & Collins, Penny K. (2007) Visual performance after overnight orthokeratology. Contact Lens and Anterior Eye, 30(1), pp. 29-36.

View at publisher

Abstract

PURPOSE: To investigate visual performance after overnight orthokeratology in terms of changes from baseline values, regression of the orthokeratology effect over time, and evaluation of the best-corrected vision after treatment. In particular, to evaluate any residual visual deficits over the duration of a day due to the abnormal corneal topography induced by orthokeratology treatment. METHOD: One eye of each of six subjects was fitted with custom designed BE orthokeratology lenses (Capricornia, Brisbane, Australia), with the fellow eye acting as a control. Unaided vision, subjective sphero-cylindrical refraction, high contrast high luminance visual acuity, low contrast high luminance visual acuity, high contrast low luminance visual acuity and letter contrast sensitivity were measured at baseline and after one night (Day 1) and eight nights (Day 8) of lens wear. Except for baseline, data were collected after overnight lens wear immediately after lens removal, and again 3, 6 and 9h after lens removal. At each time point throughout the day, the visual performance measures were evaluated with the initial refraction of the day (the 0h refraction) and also using the optimum subjective refraction at each measurement time. This method was used to evaluate the practical visual performance to be expected after orthokeratology treatment and the residual visual deficits arising from any induced corneal changes after correction of defocus. RESULTS: As expected, orthokeratology lens wear significantly changed unaided vision and refraction from baseline. However, it did not significantly affect visual acuity in different contrast conditions, or contrast sensitivity. The spherical component of refraction was the only parameter to exhibit regression over each day (p=0.021), with more stability demonstrated on Day 8 than Day 1 (p=0.012). There were no statistically significant changes of best-corrected acuity from baseline in the differing contrast and luminance conditions. CONCLUSION: Apart from the predicted improvements in unaided vision and reduction of the myopic refractive error, orthokeratology treatment was not found to significantly change any other aspects of visual acuity and contrast sensitivity. All visual performance measures exhibited stability over a 9-h period. Spherical refractive error changed significantly on Day 1 but became stable after a week of treatment. These results indicate that the corneal topography changes induced by orthokeratology do not induce changes in aberrations that are large enough to significantly diminish visual performance.

Impact and interest:

12 citations in Scopus
Search Google Scholar™

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 11388
Item Type: Journal Article
Keywords: Orthokeratology, Visual acuity, Contrast sensitivity, Myopia
DOI: 10.1016/j.clae.2006.12.001
ISSN: 1367-0484
Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300)
Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) > Vision Science (111303)
Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) > Optical Technology (111302)
Divisions: Current > Research Centres > Centre for Health Research
Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2007 Elsevier
Copyright Statement: Reproduced in accordance with the copyright policy of the publisher.
Deposited On: 09 Jan 2008
Last Modified: 29 Feb 2012 23:37

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page