Abstract
The manipulation of perimetric stimulus parameters over a given dynamic range has been reported to provide diagnostic information additional to that of changes in differential sensitivity. Preliminary studies (Flanagan et al., 1984a) have indicated that the perimetric response in retinitis pigmentosa behaves atypically over a range of stimulus combinations and strategies. The current study investigated the perimetric response of 17 retinitis pigmentosa patients of various genetic types over a range of stimulus parameters (target size, presentation time and background luminance) and test strategies (kinetic and threshold static) using the Octopus automated perimeter, the Goldmann and Tubinger bowl perimeters and the Dicon Autoperimeter 3000. Statokinetic dissociation was found to be present with large target sizes at 10 asb and 31.5 asb bowl luminances. Some patients demonstrated enhanced sensitivity to shorter stimulus presentations.
Citations:
Citation countsare sourced monthly from Scopus and Web of Science citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
| ID Code: | 11906 |
|---|---|
| Item Type: | Journal Article |
| DOI: | 10.1007/BF00160762 |
| ISSN: | 0012-4486 |
| Subjects: | Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) > Vision Science (111303) |
| Divisions: | Current > Research Centres > Centre for Health Research Current > QUT Faculties and Divisions > Faculty of Health Current > Institutes > Institute of Health and Biomedical Innovation |
| Copyright Owner: | Copyright 1986 Springer |
| Copyright Statement: | The original publication is available at SpringerLink http://www.springerlink.com |
| Deposited On: | 14 Jan 2008 |
| Last Modified: | 22 Apr 2010 03:01 |
Export: EndNote | Dublin Core | BibTeX
Repository Staff Only: item control page