Influence of rigid contact lens base curve radius on tear pump efficiency
Fink, Barbara A., hill, Richard M., & Carney, Leo G. (1992) Influence of rigid contact lens base curve radius on tear pump efficiency. Optometry and Vision Science, 69(1), pp. 60-65.
Abstract
The effects of rigid contact lens base curve radius changes on tear pump efficiency were determined by measuring oxygen uptake on six with-the-rule corneas (with toricities between 0.37 and 1.00 D) under three conditions: (1) normal open eye, (2) after 5 min of static (without blinking) wear of polymethyl methacrylate (non-gas permeable) contact lenses, and (3) after 5 min of dynamic (with blinking once every 5 s) wear of the same lenses. The difference between the oxygen uptake rates measured under static and dynamic conditions provides an index of tear pump efficiency. Each subject wore a series of five lenses: fitted on K and 0.05 or 0.10 mm steeper and flatter than the flattest corneal meridian. The overall diameter of all lenses was 8.8 mm, the optic zone was 7.4 mm, the axial edge lift was 0.09 mm, and all other parameters were constant. The contact lens fitted on K was associated with the greatest central corneal oxygen debt under static conditions, whereas the same lens also provided for the best tear exchange with the blink. In addition, better tear exchange was found to be associated with larger palpebral aperture sizes.
Citations:
Citation countsare sourced monthly from Scopus and Web of Science citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
Full-text downloads:
Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.
| ID Code: | 3202 |
|---|---|
| Item Type: | Journal Article |
| Additional Information: | l.carney@qut.edu.au |
| Additional URLs: | |
| Keywords: | Contact Lenses, Cornea/, physiology, Tears/, physiology, Adult, Blinking, Female, Humans, Male, Methylmethacrylate, Methylmethacrylates, Microelectrodes, Oxygen Consumption, Polarography |
| ISSN: | 1040-5488 |
| Subjects: | Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > PAEDIATRICS AND REPRODUCTIVE MEDICINE (111400) > Paediatrics (111403) Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) |
| Divisions: | Current > QUT Faculties and Divisions > Faculty of Health Current > Institutes > Institute of Health and Biomedical Innovation |
| Copyright Owner: | Copyright 1992 American Academy of Optometry |
| Copyright Statement: | Reproduced in accordance with the copyright policy of the publisher. |
| Deposited On: | 13 Jul 2006 |
| Last Modified: | 09 Jun 2010 22:29 |
Export: EndNote | Dublin Core | BibTeX