QUT ePrints

Rigid contact lens design equivalencies of overall diameter and axial edge lift: individual variations

Fink, Barbara A., Hill, Richard M., & Carney, Leo G. (1993) Rigid contact lens design equivalencies of overall diameter and axial edge lift: individual variations. Optometry and Vision Science, 70(9), pp. 733-738.

Abstract

We compared the effects on rigid contact lens tear pump efficiency of changes in lens overall and optic zone diameter and of changes in lens axial edge lift by measuring corneal oxygen uptake on the right eyes of six human subjects after 5 min of both static and dynamic contact lens wear. Two sets of five lenses were worn by each subject. In set 1, overall diameter varied from 8.2 to 9.4 mm in 0.3-mm steps, with the optic zone diameter being 1.4 mm smaller and a 0.09 mm axial edge lift. In set 2, axial edge lift varied from 0.05 to 0.13 mm in 0.02-mm steps; overall diameter was 8.8 mm, and optic zone diameter was 7.4 mm. For the pooled data, a 0.3-mm decrease in overall diameter was approximately equivalent to a 0.03-mm increase in axial edge lift as a means of enhancing tear pump efficiency. However, considerable intersubject differences were exhibited, with the following increases in axial edge lift being equivalent to the 0.3-mm reduction in overall diameter: 0.01, 0.01, 0.04, 0.06, 0.09, and > 0.20 mm. This illustrates that subject factors (i.e., palpebral aperture size, lid-to-cornea geometry, corneal toricity, peripheral corneal topography, lid tension) influence lens positioning, movement, and tear pump efficiency.

Impact and interest:

3 citations in Scopus
Search Google Scholar™
1 citations in Web of Science®

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

181 since deposited on 13 Jul 2006
51 in the past twelve months

Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 3205
Item Type: Journal Article
Additional Information: l.carney@qut.edu.au
Additional URLs:
Keywords: Contact Lenses, Cornea/, physiology, Adult, Comparative Study, Female, Humans, Male, Methylmethacrylate, Methylmethacrylates, Oxygen/metabolism, Polarography, Prosthesis Design, Tears/metabolism
ISSN: 1040-5488
Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300)
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 1993 American Academy of Optometry
Copyright Statement: Reproduced in accordance with the copyright policy of the publisher.
Deposited On: 13 Jul 2006
Last Modified: 09 Jun 2010 22:29

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page