QUT ePrints

The role of cardiopulmonary signals in the dynamics of the eye's wavefront aberrations

Muma, M. , Iskander, D.R., & Collins, M.J. (2010) The role of cardiopulmonary signals in the dynamics of the eye's wavefront aberrations. IEEE Transactions on Biomedical Engineering, 57(2), pp. 373-383.

[img] Accepted Version (PDF 9MB)
Administrators only | Request a copy from author

    View at publisher

    Abstract

    Abstract—The role of cardiopulmonary signals in the dynamics of wavefront aberrations in the eye has been examined. Synchronous measurement of the eye’s wavefront aberrations, cardiac function, blood pulse, and respiration signals were taken for a group of young, healthy subjects. Two focusing stimuli, three breathing patterns, as well as natural and cycloplegic eye conditions were examined. A set of tools, including time–frequency coherence and its metrics, has been proposed to acquire a detailed picture of the interactions of the cardiopulmonary system with the eye’s wavefront aberrations. The results showed that the coherence of the blood pulse and its harmonics with the eye’s aberrations was, on average, weak (0.4 ± 0.15), while the coherence of the respiration signal with eye’s aberrations was, on average, moderate (0.53 ± 0.14). It was also revealed that there were significant intervals during which high coherence occurred. On average, the coherence was high (>0.75) during 16% of the recorded time, for the blood pulse, and 34% of the time for the respiration signal. A statistically significant decrease in average coherence was noted for the eye’s aberrations with respiration in the case of fast controlled breathing (0.5 Hz). The coherence between the blood pulse and the defocus was significantly larger for the far target than for the near target condition. After cycloplegia, the coherence of defocus with the blood pulse significantly decreased, while this was not the case for the other aberrations. There was also a noticeable, but not statistically significant, increase in the coherence of the comatic term and respiration in that case. By using nonstationary measures of signal coherence, a more detailed picture of interactions between the cardiopulmonary signals and eye’s wavefront aberrations has emerged.

    Impact and interest:

    10 citations in Scopus
    Search Google Scholar™
    10 citations in Web of Science®

    Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

    These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

    Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

    ID Code: 38539
    Item Type: Journal Article
    Keywords: Biomedical Signal processing, Eye, Pulse and respiration, Time-varying coherence, Wavefront sensing
    DOI: 10.1109/TBME.2009.2032531
    ISSN: 0018-9294
    Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300) > Optometry and Ophthalmology not elsewhere classified (111399)
    Divisions: Current > QUT Faculties and Divisions > Faculty of Health
    Current > Institutes > Institute of Health and Biomedical Innovation
    Current > Schools > School of Optometry & Vision Science
    Copyright Owner: Copyright 2010 IEEE.
    Deposited On: 17 Nov 2010 12:24
    Last Modified: 01 Mar 2012 00:27

    Export: EndNote | Dublin Core | BibTeX

    Repository Staff Only: item control page