Commissioning of a Geant4 based treatment plan simulation tool : linac model and dicom-rt interface
Cornelius, Iwan, Poole, Christopher, Langton, Christian M., Hill, Brendan, Middlebrook, Nigel, & Oborn, Brad (2011) Commissioning of a Geant4 based treatment plan simulation tool : linac model and dicom-rt interface. .
Abstract
A Geant4 based simulation tool has been developed to perform Monte Carlo modelling of a 6 MV VarianTM iX clinac. The computer aided design interface of Geant4 was used to accurately model the LINAC components, including the Millenium multi-leaf collimators (MLCs). The simulation tool was verified via simulation of standard commissioning dosimetry data acquired with an ionisation chamber in a water phantom. Verification of the MLC model was achieved by simulation of leaf leakage measurements performed using GafchromicTM film in a solid water phantom. An absolute dose calibration capability was added by including a virtual monitor chamber into the simulation. Furthermore, a DICOM-RT interface was integrated with the application to allow the simulation of treatment plans in radiotherapy. The ability of the simulation tool to accurately model leaf movements and doses at each control point was verified by simulation of a widely used intensity-modulated radiation therapy (IMRT) quality assurance (QA) technique, the chair test.
Citations:
Citation countsare sourced monthly from Scopus and Web of Science citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
Full-text downloads:
Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.
| ID Code: | 41556 |
|---|---|
| Item Type: | Journal Article |
| Keywords: | geant4, radiotherapy, chair test, quality assurance, imrt, monte carlo, rapidarc |
| Subjects: | Australian and New Zealand Standard Research Classification > PHYSICAL SCIENCES (020000) > OTHER PHYSICAL SCIENCES (029900) > Medical Physics (029903) |
| Divisions: | Past > QUT Faculties & Divisions > Faculty of Science and Technology Current > Institutes > Institute of Health and Biomedical Innovation Past > Schools > Physics |
| Copyright Owner: | Copyright 2011 The Authors |
| Deposited On: | 05 May 2011 09:18 |
| Last Modified: | 11 Aug 2011 22:54 |
Export: EndNote | Dublin Core | BibTeX
Repository Staff Only: item control page