A radiological method to determine the accuracy of motion capture marker placement on palpable anatomical landmarks through a shoe
Bishop, Chris, Thewlis, Dominic, Uden, Hayley, Ogilvie, Denise, & Paul, Gunther (2011) A radiological method to determine the accuracy of motion capture marker placement on palpable anatomical landmarks through a shoe. Footwear Science, 3(3), pp. 169-177.
Abstract
The accuracy of marker placement on palpable surface anatomical landmarks is an important consideration in biomechanics. Although marker placement reliability has been studied in some depth, it remains unclear whether or not the markers are accurately positioned over the intended landmark in order to define the static position and orientation of the segment. A novel method using commonly available X-ray imaging was developed to identify the accuracy of markers placed on the shoe surface by palpating landmarks through the shoe. An anterior–posterior and lateral–medial X-ray was taken on 24 participants with a newly developed marker set applied to both the skin and shoe. The vector magnitude of both skin- and shoe-mounted markers from the anatomical landmark was calculated, as well as the mean marker offset between skin- and shoe-mounted markers. The accuracy of placing markers on the shoe relative to the skin-mounted markers, accounting for shoe thickness, was less than 5mm for all markers studied. Further, when using the developed guidelines provided in this study, the method was deemed reliable (Intra-rater ICCs¼0.50–0.92). In conclusion, the method proposed here can reliably assess marker placement accuracy on the shoe surface relative to chosen anatomical landmarks beneath the skin.
Citations:
Citation countsare sourced monthly from Scopus and Web of Science citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
Full-text downloads:
Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.
| ID Code: | 49008 |
|---|---|
| Item Type: | Journal Article |
| Keywords: | Anatomical Markers, Kinematic Model, X-Ray, Reliability, Foot and Ankle |
| DOI: | 10.1080/19424280.2011.635386 |
| ISSN: | 1942-4280 |
| Divisions: | Current > QUT Faculties and Divisions > Faculty of Health Current > Schools > School of Public Health & Social Work |
| Copyright Owner: | Copyright Taylor & Francis 2011 |
| Deposited On: | 07 Mar 2012 10:44 |
| Last Modified: | 07 Mar 2012 12:23 |
Export: EndNote | Dublin Core | BibTeX
Repository Staff Only: item control page