QUT ePrints

The accuracy of a new system for estimating organ volume using ultrasound

Hughes, S.W., D'Arcy, T.J. , Maxwell, D.J. , Saunders, J.E. , Chinn, S. , & Sheppard , R.J. (1997) The accuracy of a new system for estimating organ volume using ultrasound. Physiological Measurement, 18(1), pp. 73-84.

View at publisher

Abstract

A new system is described for estimating volume from a series of multiplanar 2D ultrasound images. Ultrasound images are captured using a personal computer video digitizing card and an electromagnetic localization system is used to record the pose of the ultrasound images. The accuracy of the system was assessed by scanning four groups of ten cadaveric kidneys on four different ultrasound machines. Scan image planes were oriented either radially, in parallel or slanted at 30 C to the vertical. The cross-sectional images of the kidneys were traced using a mouse and the outline points transformed to 3D space using the Fastrak position and orientation data. Points on adjacent region of interest outlines were connected to form a triangle mesh and the volume of the kidneys estimated using the ellipsoid, planimetry, tetrahedral and ray tracing methods. There was little difference between the results for the different scan techniques or volume estimation algorithms, although, perhaps as expected, the ellipsoid results were the least precise. For radial scanning and ray tracing, the mean and standard deviation of the percentage errors for the four different machines were as follows: Hitachi EUB-240, −3.0 ± 2.7%; Tosbee RM3, −0.1 ± 2.3%; Hitachi EUB-415, 0.2 ± 2.3%; Acuson, 2.7 ± 2.3%.

Impact and interest:

9 citations in Scopus
Search Google Scholar™
9 citations in Web of Science®

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

117 since deposited on 30 Apr 2012
82 in the past twelve months

Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 50017
Item Type: Journal Article
Keywords: ultrasound, 3D, computed tomography, CT, magnetic resonance, MR, fetal livers, fetal organ volume
DOI: 10.1088/0967-3334/18/1/006
ISSN: 0967-3334
Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > CLINICAL SCIENCES (110300) > Radiology and Organ Imaging (110320)
Divisions: Current > Schools > School of Chemistry, Physics & Mechanical Engineering
Copyright Owner: Copyright 1997 IOP Publishing Ltd
Deposited On: 01 May 2012 08:49
Last Modified: 01 May 2012 14:44