Ingram, David M.E., Schaub, Pascal, Campbell, Duncan A., & Taylor, Richard R. (2012) Evaluation of precision time synchronisation methods for substation applications. In Lee, Kang & Sankar, Krishna (Eds.) Proceedings 2012 International IEEE Symposium on Precision Clock Synchronization for Measurement, Control and Communication, IEEE, San Francisco, CA, pp. 37-42.

View at publisher

Abstract

Many substation applications require accurate time-stamping. The performance of systems such as Network Time Protocol (NTP), IRIG-B and one pulse per second (1-PPS) have been sufficient to date. However, new applications, including IEC 61850-9-2 process bus and phasor measurement, require accuracy of one microsecond or better. Furthermore, process bus applications are taking time synchronisation out into high voltage switchyards where cable lengths may have an impact on timing accuracy. IEEE Std 1588, Precision Time Protocol (PTP), is the means preferred by the smart grid standardisation roadmaps (from both the IEC and US National Institute of Standards and Technology) of achieving this higher level of performance, and integrates well into Ethernet based substation automation systems. Significant benefits of PTP include automatic path length compensation, support for redundant time sources and the cabling efficiency of a shared network. This paper benchmarks the performance of established IRIG-B and 1-PPS synchronisation methods over a range of path lengths representative of a transmission substation. The performance of PTP using the same distribution system is then evaluated and compared to the existing methods to determine if the performance justifies the additional complexity. Experimental results show that a PTP timing system maintains the synchronising performance of 1-PPS and IRIG-B timing systems, when using the same fibre optic cables, and further meets the needs of process buses in large substations.

Impact and interest:

1 citations in Scopus
Search Google Scholar™

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

181 since deposited on 20 Aug 2012
81 in the past twelve months

Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 53218
Item Type: Conference Paper
Keywords: Ethernet networks, IEC 61850, IEEE 1588, performance evaluation, power transmission, protective relaying, Precision Time Protocol, smart grids, time measurement
DOI: 10.1109/ISPCS.2012.6336630
ISBN: 978-145771715-4
Subjects: Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > ELECTRICAL AND ELECTRONIC ENGINEERING (090600) > Power and Energy Systems Engineering (excl. Renewable Power) (090607)
Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > ELECTRICAL AND ELECTRONIC ENGINEERING (090600) > Electrical and Electronic Engineering not elsewhere classified (090699)
Australian and New Zealand Standard Research Classification > TECHNOLOGY (100000) > COMMUNICATIONS TECHNOLOGIES (100500) > Computer Communications Networks (100503)
Divisions: Current > Schools > School of Electrical Engineering & Computer Science
Copyright Owner: Copyright 2012 IEEE
Deposited On: 21 Aug 2012 08:22
Last Modified: 21 Feb 2013 07:05

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page