The effect of under and over refractive correction on visual performance and spectacle lens acceptance

Atchison, David A., Schmid, Katrina L., Edwards, Katie P., Muller, Sharon M., & Robotham, Jayne (2001) The effect of under and over refractive correction on visual performance and spectacle lens acceptance. Ophthalmic and Physiological Optics, 21(4), pp. 255-261.

View at publisher

Abstract

As a follow-on from a previous study by Miller, Kris and Griffiths (1997, Optom. Vis. Sci.84, 521–526), we investigated the effect of small prescription errors on spatial visual performance and spectacle lens acceptability. We included both negative and positive errors and binocular and monocular errors. Data were collected on 15 young adult subjects. Clinical measures were taken of pupil size, ocular dominance, binocular visual acuity, negative and positive relative accommodation, distance and near heterophorias, and stereopsis. Visual performance was measured with the best correction and for ±0.50 D spherical binocular and monocular errors. Subjects wore spectacles, each containing a different error in turn, for 2 days and compared them with a reference pair. Following the wearing period subjects assessed the performance of the spectacles by completing a short questionnaire. The only ocular tests for which these small prescription errors had significant effects were binocular visual acuity and negative relative accommodation. No significant relationship was observed between any of the clinical test results and overall lens acceptance. Despite this, the reference pair was generally perceived as better than the test pairs containing errors, and a considerable proportion of subjects reported pairs with errors as being unacceptable. In conclusion, the questionnaire findings support the need for both accurate monocular and binocular refractions. Subjects differed in their criteria for judging lens acceptability.

Impact and interest:

21 citations in Scopus
Search Google Scholar™
19 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 5482
Item Type: Journal Article
Refereed: Yes
Additional Information: For more information, please refer to the journal’s website (see link) or contact the author. Author contact details: d.atchison@qut.edu.au
DOI: 10.1046/j.1475-1313.2001.00588.x
ISSN: 0275-5408
Subjects: Australian and New Zealand Standard Research Classification > MEDICAL AND HEALTH SCIENCES (110000) > OPTOMETRY AND OPHTHALMOLOGY (111300)
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2001 Blackwell Publishing
Copyright Statement: The definitive version is available at www.blackwell-synergy.com
Deposited On: 17 Nov 2006 00:00
Last Modified: 15 Jan 2009 07:15

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page