Utilizing Wide-Area Signals for off-center SVCs to damp interarea oscillations

Goldoost Soloot, Reza, Mishra, Yateendra, & Ledwich, Gerard (2013) Utilizing Wide-Area Signals for off-center SVCs to damp interarea oscillations. In Proceedings of the 2013 IEEE Power and Energy Society General Meeting (PES), IEEE, Vancouver, British Columbia, Canada, pp. 1-5.

View at publisher

Abstract

Wide-Area Measurement Systems (WAMS) provide the opportunity of utilizing remote signals from different locations for the enhancement of power system stability. This paper focuses on the implementation of remote measurements as supplementary signals for off-center Static Var Compensators (SVCs) to damp inter-area oscillations. Combination of participation factor and residue method is used for the selection of most effective stabilizing signal. Speed difference of two generators from separate areas is identified as the best stabilizing signal and used as a supplementary signal for lead-lag controller of SVCs. Time delays of remote measurements and control signals is considered. Wide-Area Damping Controller (WADC) is deployed in Matlab Simulink framework and is tested under different operating conditions. Simulation results reveal that the proposed WADC improve the dynamic characteristic of the system significantly.

Impact and interest:

0 citations in Scopus
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

159 since deposited on 11 Nov 2013
25 in the past twelve months

Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 64153
Item Type: Conference Paper
Refereed: Yes
Additional URLs:
Keywords: power system stability, Static Var Compensator (SVC), interarea oscillations, time delay, stabilizing signal, Wide-Area Measurements
DOI: 10.1109/PESMG.2013.6672785
ISBN: 978-1-4799-1303-9
Subjects: Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > ELECTRICAL AND ELECTRONIC ENGINEERING (090600) > Power and Energy Systems Engineering (excl. Renewable Power) (090607)
Divisions: Current > Schools > School of Electrical Engineering & Computer Science
Current > QUT Faculties and Divisions > Science & Engineering Faculty
Funding:
Copyright Owner: Copyright 2013 Please consult the authors
Deposited On: 11 Nov 2013 01:12
Last Modified: 04 Dec 2016 02:33

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page