Visual performance with lenses correcting peripheral refractive errors

Atchison, David A., Mathur, Ankit, & Varnas, Saulius R. (2013) Visual performance with lenses correcting peripheral refractive errors. Optometry and Vision Science, 90(11), pp. 1304-1311.

View at publisher



To design and manufacture lenses to correct peripheral refraction along the horizontal meridian and to determine whether these resulted in noticeable improvements in visual performance.


Subjective refraction of a low myope was determined on the basis of best peripheral detection acuity along the horizontal visual field out to ±30° for both horizontal and vertical gratings. Subjective refraction was compared to objective refractions using a COAS-HD aberrometer. Special lenses were made to correct peripheral refraction, based on designs optimized with and without smoothing across a 3 mm diameter square aperture. Grating detection was retested with these lenses. Contrast thresholds of 1.25’ spots were determined across the field for the conditions of best correction, on-axis correction, and the special lenses.


The participant had high relative peripheral hyperopia, particularly in the temporal visual field (maximum 2.9 D). There were differences > 0.5D between subjective and objective refractions at a few field angles. On-axis correction reduced peripheral detection acuity and increased peripheral contrast threshold in the peripheral visual field, relative to the best correction, by up to 0.4 and 0.5 log units, respectively. The special lenses restored most of the peripheral vision, although not all at angles to ±10°, and with the lens optimized with aperture-smoothing possibly giving better vision than the lens optimized without aperture-smoothing at some angles.


It is possible to design and manufacture lenses to give near optimum peripheral visual performance to at least ±30° along one visual field meridian. The benefit of such lenses is likely to be manifest only if a subject has a considerable relative peripheral refraction, for example of the order of 2 D.

Impact and interest:

5 citations in Scopus
Search Google Scholar™
5 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

67 since deposited on 03 Dec 2013
29 in the past twelve months

Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 64955
Item Type: Journal Article
Refereed: Yes
Additional URLs:
Keywords: lenses, visual acuity, peripheral vision, peripheral refraction, detection
DOI: 10.1097/OPX.0000000000000033
ISSN: 1040-5488
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Current > Schools > School of Optometry & Vision Science
Copyright Owner: Copyright 2013 American Academy of Optometry