QUT ePrints

Development of a method to validate computer models of the spine for scoliosis correction surgery simulation

Cunningham, Helen, Adam, Clayton J., & Pearcy, Mark J. (2006) Development of a method to validate computer models of the spine for scoliosis correction surgery simulation. In McPhee, Bruce (Ed.) Spine Society of Australia, April 28-30, 2006, Sydney.

Abstract

DEVELOPMENT OF A METHOD TO VALIDATE COMPUTER MODELS OF THE SPINE FOR SCOLIOSIS CORRECTION SURGERY SIMULATION

Helen Cunningham, Clayton J Adam, Mark J Pearcy

School of Engineering Systems, Queensland University of Technology, Brisbane, Australia

Introduction Endoscopic single rod anterior fusion surgery for the treatment of adolescent idiopathic scoliosis (AIS) offers the advantages of improved cosmetic results, the fusion of fewer segments and faster patient rehabilitation. The development of a patient-specific finite element model of the spine to be used to predict post-operative biomechanical outcomes of anterior AIS surgery will improve the pre-operative planning and performance of scoliosis instrumentation. This study aims to develop a methodology for validating the finite element modelling approach to scoliosis surgical planning by producing biomechanical data for movements of ovine lumbar spines both with and without anterior rod scoliosis instrumentation.

Methods Ovine lumbar spine specimens were CT scanned, dissected and instrumented across four levels (L2-L5) with a generic anterior single rod and screw implant for scoliosis correction. A displacement controlled 6 degree-of-freedom robotic facility was used to perform biomechanical testing on the spine segments for rotations of ±4 degrees in flexion/extension and lateral bending, and ±3 degrees in axial rotation. The tests were repeated with the rod removed. Resistive force and moment data was recorded using a force transducer and strain gauges on the surface of the rod yielded torsion and bending moment strain data, recorded on a data logger. All data was synchronised with the robot position data and filtered using moving average methods. The stiffness of the spines for each movement was calculated in units of Nm/degree of rotation.

Results As expected the results reflect the variability found in biological materials. The similarities of behaviour profiles however, support the use of this method for FE model validation. The addition of the rod caused an increase in stiffness for each movement. This increase was 17±7% and 23±10% for left and right axial rotation, 93±35% and 73±50% for left and right lateral bending, and 78±46% and 67±35% for flexion and extension respectively. Recorded strains on the rod surface did not exceed 400με.

Discussion The outcomes of this study have provided an experimental method for validating behaviour predicted by finite element models of the spine fitted with anterior scoliosis instrumentation. Using the CT scans of the ovine spines along with documentation of the experimental positioning of the specimens, the testing conditions can be simulated in a finite element model and the experimental and predicted biomechanical outcomes compared. The study also offers comparative information about the relative stiffness of the spine with and without scoliosis instrumentation.

Impact and interest:

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

98 since deposited on 13 Apr 2007
1 in the past twelve months

Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 6919
Item Type: Conference Paper
Subjects: Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > BIOMEDICAL ENGINEERING (090300) > Biomechanical Engineering (090302)
Divisions: Past > QUT Faculties & Divisions > Faculty of Built Environment and Engineering
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2006 (please consult author)
Deposited On: 13 Apr 2007
Last Modified: 09 Jun 2010 22:39

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page