Thermal effects of cement mantle thickness for hip resurfacing

Little, J. Paige, Gray, Hans, Murray, David W., Beard, David J., & Gill, Harinderjit S. (2007) Thermal effects of cement mantle thickness for hip resurfacing. Journal of Arthroplasty.

Abstract

Hybrid hip resurfacing arthroplasty (HRA), with uncemented acetabular and cemented femoral fixation is increasingly popular as an alternative to total hip replacement. There is concern about femoral neck fractures and long term survival has not yet been demonstrated. Thermal necrosis may be an important factor for neck fracture and will affect the viability of the femoral bone. This cadaveric study investigated the thermal effect of thick (1.5mm, n=3) and thin (0.5mm, n=3) cement mantles; five thermocouples were used to record temperature at the femoral bone/cement interface during HRA. The maximum recorded temperatures were significantly higher when a thick cement mantle is used (45.4 C), compared to a thin cement mantle (32.7 C). In order to reduce the potential for thermal necrosis, the thin cement mantle technique is recommended.

Impact and interest:

30 citations in Scopus
Search Google Scholar™

Citation countsare sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

336 since deposited on 08 May 2007
31 in the past twelve months

Full-text downloadsdisplays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 7459
Item Type: Other
Subjects: Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > BIOMEDICAL ENGINEERING (090300) > Biomechanical Engineering (090302)
Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > BIOMEDICAL ENGINEERING (090300) > Biomedical Instrumentation (090303)
Divisions: Past > QUT Faculties & Divisions > Faculty of Built Environment and Engineering
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2007 (The authors)
Deposited On: 08 May 2007
Last Modified: 29 Feb 2012 23:57

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page