Comparison of ultraviolet data from co-located instruments from the US EPA Brewer Spectrophotometer Network and the UADA UVB Monitoring and Research Program

Kimlin, Michael G., Slusser, James R., Schallhorn, Kathryn A., Lantz, Kathleen, & Meltzer, Richard (2005) Comparison of ultraviolet data from co-located instruments from the US EPA Brewer Spectrophotometer Network and the UADA UVB Monitoring and Research Program. Optical Engineering, 44(4), 041008-041088.

View at publisher


Several ground-based ultraviolet (UV) monitoring networks exist in the United States, each of which is unique in the instrumentation employed for measurements. Two of these UV networks are the U.S. Environmental Protection Agency's (EPA's) Brewer Spectrophotometer Network and the U.S. Department of Agriculture's (USDA's) UV-B monitoring network, with a combined instrument total of 52 sites, with 32 sites located in the mainland United States. The Brewer records full sky spectra from 287 to 363 nm with 0.55-nm resolution, whereas the USDA instrument is a broadband device that measures broadband erythemally weighted UV data. To date, limited comparisons of data collected from these networks have been analyzed for comparative and quality assurance (QA) purposes. The data we use is taken from sites where instruments from each program are colocated, namely, Big Bend National Park, Texas, and Everglades National Park, Florida. To reduce the contribution of errors in the Brewer-based instruments, the raw data is corrected for stray light rejection, the angular response of the full sky diffuser, the temperature dependence of the instruments, and the temporal variation. This reduces the estimated errors of the absolute irradiance values of each Brewer spectral measurement to approximately ±5%. The estimated uncertainty of the USDA instruments is approximately ±6% with a systematic bias of (–13 to 5% depending on the total ozone) and is comprised of (1) standard lamp measurement errors, (2) spectral response determination, and (3) the angular response of the diffuser. We perform comparisons between the Brewer spectrally integrated and erythemally weighted UV irradiance measurements and the data collected by the broadband erythemal UV meters at colocated sites between 1997 through to 2002. ©2005 Society of Photo-Optical Instrumentation Engineers.

Impact and interest:

4 citations in Scopus
Search Google Scholar™
3 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 7745
Item Type: Journal Article
Refereed: Yes
Additional Information: For more information, please refer to the publisher's website (link above) or contact the author:
DOI: 10.1117/1.1885470
ISSN: 0091-3286
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: Copyright 2005 SPIE
Deposited On: 04 Jun 2007 00:00
Last Modified: 29 Feb 2012 13:14

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page