Metrological assessment of a portable analyzer for monitoring the particle size distribution of ultrafine particles

Stabile, Luca, Cauda, Emanuele, Marini, Sara, & Buonanno, Giorgio (2014) Metrological assessment of a portable analyzer for monitoring the particle size distribution of ultrafine particles. Annals of Occupational Hygiene, 58(7), pp. 860-876.

View at publisher

Abstract

Adverse health effects caused by worker exposure to ultrafine particles have been detected in recent years. The scientific community focuses on the assessment of ultrafine aerosols in different microenvironments in order to determine the related worker exposure/dose levels. To this end, particle size distribution measurements have to be taken along with total particle number concentrations. The latter are obtainable through hand-held monitors. A portable particle size distribution analyzer (Nanoscan SMPS 3910, TSI Inc.) was recently commercialized, but so far no metrological assessment has been performed to characterize its performance with respect to well-established laboratory- based instruments such as the scanning mobility particle sizer (SMPS) spectrometer. The present paper compares the aerosol monitoring capability of the Nanoscan SMPS to the laboratory SMPS in order to evaluate whether the Nanoscan SMPS is suitable for field experiments designed to characterize particle exposure in different microenvironments. Tests were performed both in a Marple calm air chamber, where fresh diesel particulate matter and atomized dioctyl phthalate particles were monitored, and in microenvironments, where outdoor, urban, indoor aged, and indoor fresh aerosols were measured. Results show that the Nanoscan SMPS is able to properly measure the particle size distribution for each type of aerosol investigated, but it overestimates the total particle number concentration in the case of fresh aerosols. In particular, the test performed in the Marple chamber showed total concentrations up to twice those measured by the laboratory SMPS—likely because of the inability of the Nanoscan SMPS unipolar charger to properly charge aerosols made up of aggregated particles. Based on these findings, when field test exposure studies are conducted, the Nanoscan SMPS should be used in tandem

Impact and interest:

7 citations in Scopus
Search Google Scholar™
7 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 88510
Item Type: Journal Article
Refereed: Yes
Keywords: diesel particulate matter, dioctyl phthalate particles, laboratory SMPS, metrological assessment;, Nanoscan SMPS, occupational aerosol, particle size distribution, portable analyzer, total particle number concentration, ultrafine particles
DOI: 10.1093/annhyg/meu025
ISSN: 1475-3162
Divisions: Current > Schools > School of Chemistry, Physics & Mechanical Engineering
Current > QUT Faculties and Divisions > Science & Engineering Faculty
Deposited On: 22 Oct 2015 02:02
Last Modified: 22 Oct 2015 02:02

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page