Reliability and validity of objective measures of physical activity in youth with cerebral palsy who are ambulatory

O'Neil, Margaret E., Fragala-Pinkham, Maria A., Lennon, Nancy, George, Ameeka, Forman, Jeffrey L., & Trost, Stewart G. (2016) Reliability and validity of objective measures of physical activity in youth with cerebral palsy who are ambulatory. Physical Therapy, 96(1), pp. 37-45.

View at publisher

Abstract

BACKGROUND

  • Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP.

OBJECTIVE

  • The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP.

METHODS

  • Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials.

RESULTS

  • All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials.

LIMITATIONS

  • This PA protocol consisted of controlled activity trials.

CONCLUSIONS

  • Accelerometers provide valid and reliable measures of PA intensity among youth with CP.

Impact and interest:

0 citations in Scopus
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 92463
Item Type: Journal Article
Refereed: Yes
DOI: 10.2522/ptj.20140201
ISSN: 0031-9023
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Institutes > Institute of Health and Biomedical Innovation
Current > Schools > School of Exercise & Nutrition Sciences
Copyright Owner: Copyright 2016 American Physical Therapy Association
Deposited On: 01 Feb 2016 00:28
Last Modified: 15 Nov 2016 22:52

Export: EndNote | Dublin Core | BibTeX

Repository Staff Only: item control page