Section moment capacity tests of rivet fastened rectangular hollow flange channel beams

Siahaan, Ropalin, Mahendran, Mahen, & Poologanathan, Keerthan (2016) Section moment capacity tests of rivet fastened rectangular hollow flange channel beams. Journal of Constructional Steel Research, 125, pp. 252-262.

[img] Accepted Version (PDF 182kB)
Administrators only until October 2017 | Request a copy from author
[img] Tables (PDF 60kB)
Supplemental Material.
Administrators only until October 2017 | Request a copy from author
[img] Figures (PDF 1MB)
Supplemental Material.
Administrators only until October 2017 | Request a copy from author

View at publisher

Abstract

This paper presents the details of an experimental investigation on the section moment capacities of rivet fastened Rectangular Hollow Flange Channel Beams (RHFCB). The rivet fastened RHFCB is a new type of cold-formed steel section, an extension to the widely researched hollow flange beams, shown to have capacities more typically associated with hot-rolled steel beams. It is characterized by a unique geometry, consisting of two rectangular hollow flanges and a web. Unlike other cold-formed sections, the RHFCB has improved capacity due to its mono-symmetric shape and the absence of free edges. The RHFCB manufacturing involves fastening two hollow flanges to a web, utilizing inexpensive intermittent self-pierced rivet fastening. This enables designers to develop optimum sections with varying web and flange thicknesses, therefore delaying the onset of other buckling failures due to slender web element. Various researches have been carried out to investigate the behavior of continuously welded hollow flange beams but little is known on the behavior of RHFCBs. Hence this paper investigates the section moment capacities of rivet fastened RHFCBs. Fifteen section moment capacity tests were conducted to investigate the behavior of RHFCB flexural members. The reduction in section moment capacities from having continuous weld to intermittent rivet connection at its web-flange junction was also investigated. The ultimate moment capacities from the tests were compared with current steel design standards: AS/NZS 4600, AS 4100 and AISI S100. The paper also explores the suitability of the Direct Strength Method, with modification being proposed, from the results obtained from this investigation.

Impact and interest:

2 citations in Scopus
Search Google Scholar™
1 citations in Web of Science®

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 98797
Item Type: Journal Article
Refereed: Yes
Keywords: Hollow Flange Beams, Cold-formed Steel Structures, Section Moment Capacity Tests, Intermittent Rivet Connection, Direct Strength Method, Design Rules, Local Buckling
DOI: 10.1016/j.jcsr.2016.06.021
ISSN: 0143-974X
Subjects: Australian and New Zealand Standard Research Classification > ENGINEERING (090000) > CIVIL ENGINEERING (090500) > Structural Engineering (090506)
Divisions: Current > QUT Faculties and Divisions > Science & Engineering Faculty
Copyright Owner: Copyright 2016 Elsevier
Copyright Statement: Licensed under the Creative Commons Attribution; Non-Commercial; No-Derivatives 4.0 International. Doi: 10.1016/j.jcsr.2016.06.021