A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases

Cornish, Bruce H. and Thomas, Brian J. and Ward, Leigh C. and Hirst, Cherrell and Bunce, Ian H. (2002) A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases . Angiology 53(1):pp. 41-47.

Full text available as:
PDF (Author version) - Requires Adobe Acrobat Reader or other PDF viewer.

Abstract

Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb. Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p < 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.

Item Type:Journal Article
RM Number:2003000397
Status:Published
Subjects:Subjects UNSPECIFIED
ID Code:9858
Deposited By:Bozzetto, Adam
Deposited On:01 October 2007
Alternative Locations:http://ang.sagepub.com/
Copyright Owner:Copyright 2002 Sage Publications