QUT ePrints

Browse By Person: Gregory, Shaun

 Up a level
Export as [feed] RSS 1.0 [feed] Atom [feed] RSS 2.0
Group by: Item Type | Date
Number of items: 8.

Journal Article

Gregory, Shaun, Timms, Daniel, Gaddum, Nick, Mason, David, & Fraser, John (2011) Biventricular assist devices: A technical review. Annals of Biomedical Engineering, 39(9), pp. 2313-2328.
Number of citations in Scopus 9
Number of citations in Web of Science 6

Gregory, Shaun, Timms, Daniel, Gaddum, Nick, McDonald, Charles, Pearcy, Mark, & Fraser, John (2011) In vitro evaluation of a compliant inflow cannula reservoir to reduce suction events with extracorporeal rotary ventricular assist device support. Artificial Organs: replacement, recovery, and regeneration, 35(8), pp. 765-772.
Number of citations in Scopus 2
Number of citations in Web of Science 2

Timms, Daniel L., Gregory, Shaun D., Greatrex, Nicholas A., Pearcy, Mark J., Fraser, John F., & Steinseifer, Ulrich (2010) A compact mock circulation loop for the in vitro testing of cardiovascular devices. Artificial Organs.
Number of citations in Scopus 9
Number of citations in Web of Science 3

Gregory, Shaun, Greatrex, Nicholas, Timms, Daniel L., Gaddum, Nicholas Richard, Pearcy, Mark J., & Fraser, John F. (2010) Simulation and enhancement of a cardiovascular device test rig. Journal of Simulation, 4(1), pp. 34-41.
Number of full-text downloads 60
Number of citations in Scopus 6

Timms, Daniel, Gregory, Shaun, Hsu, Po-Lin, Thomson, Bruce, Pearcy, Mark, McNeil, Keith, et al. (2010) Atrial versus ventricular cannulation for a rotary ventricular assist device. Artificial Organs, 34(9), pp. 714-720.
Number of citations in Scopus 5
Number of citations in Web of Science 5

Gregory, Shaun, Timms, Daniel, Tansley, Geoff, & Pearcy, Mark J. (2009) A naturally shaped silicone ventricle evaluated in a mock circulation loop : a preliminary study. Journal of Medical Engineering and Technology, 33(3), pp. 185-191.
Number of full-text downloads 115
Number of citations in Scopus 4

Conference Paper

Gregory, Shaun, Stevens, Michael, Timms, Daniel L., & Pearcy, Mark J. (2011) Replication of the Frank-Starling response in a Mock Circulation loop. In 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2011), 30 August - 3 September 2011, Boston Marriott Copley Place Hotel, Boston, MA. (In Press)
Number of full-text downloads 124

QUT Thesis

Gregory, Shaun David (2009) Simulation and development of a mock circulation loop with variable compliance. Masters by Research thesis, Queensland University of Technology.
Number of full-text downloads 1,650

This list was generated on Sat May 25 05:44:53 2013 EST.