QUT QUT ePrints

Subject: 249902 Medical Physics


Number of items: 9.

Iskander, D.Robert (2006) A parametric approach to measuring limbus corneae from digital images. IEEE Transactions on Biomedical Engineering 53(6):pp. 1134-1140.

Aimes, Ronald T. and Zijlstra, Andries and Hooper, John D. and Ogbourne, Steven M. and Sit, Mae-le and Fuchs, Simone and Gotley, David C. and Quigley, James P. and Antalis, Toni M. (2003) Endothelial cell serine proteases expressed during vascular morphogenesis and angiogenesis. Thrombosis and Haemostasis 89(3):pp. 561-572.

Wood, Stephen J. and Yucel, Murat and Wellard, R. Mark and Harrison, Ben J. and Clarke, Kerrie and Velakoulis, Dennis and Pantelis, Christos and Fornito, Alex (2007) Evidence for neuronal dysfunction in the anterior cingulate of patients with schizophrenia: A proton magnetic resonance spectroscopy study at 3T. Schizophrenia Research 94(1-3):pp. 328-331.

Briellmann, Regula S. and Wellard, R. Mark and Jackson, Graeme D. (2005) Magnetic resonance spectroscopy in epilepsy, in Gillard, Jonathan H. and Waldman, Adam D. and Barker, Peter B., Eds. Clinical MR neuroimaging diffusion, perfusion and spectroscopy, chapter 29, pages pp. 488-508. Cambridge University Press.

Hetherington, Hoby and Petroff, Ognen A. and Jackson, Graeme D. and Kuzniecky, Ruben I. and Briellmann, Regula S. and Wellard, R. Mark (2005) Magnetic resonance spectroscopy: Principles and techniques-Biochemistry for magnetic resonance spectroscopy: Clinical applications of magnetic resonance spectroscopy in epilepsy, in Kuzniecky, Ruben I. and Jackson, Graeme D., Eds. Magnetic Resonance in Epilepsy, Neuroimaging Techniques, chapter 13, pages pp. 333-385. Elsevier Academic Press.

Hopper, Tim A. J. and Timperley, A. John and Crawford, Ross W. and Slaughter, Richard E. and Pope, James M. (2004) MRI can identify high intensity bands around implants that correspond to radiolucent lines on X-Ray: an ex vivo study of sheep acetabulae . Clinical Orthopaedics and Related Research 427:pp. 127-131.

Kairn, Tanya and Cassidy, D. and Sandford, Peta M. and Fielding, Andrew L. (2008) Radiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment. Physics in Medicine and Biology 53(14):pp. 3903-3919.

Gardner, Trevor N. and Mishra, Sanjay K. and Marks, Laurence (2004) The role of Osteogenic Index, Octahedral Shear Stress and Dilational stress in the ossification of a fracture callus. Medical Engineering & Physics 26(6):pp. 493-501.

Brown, Cameron P. and Hughes, Stephen W. and Crawford, Ross C. and Oloyede, Adekunle (2007) Ultrasound assessment of articular cartilage: Analysis of the frequency profile of reflected signals from naturally and artificially degraded samples. Connective Tissue Research 48(6):pp. 277-285.

This list was generated on Sat Oct 11 12:32:12 EST 2008.