Taller staff occupationally exposed to less radiation to the temple in cardiac procedures, but risk higher doses during vascular cases

, , , , Anderson, Rebecca, & (2020) Taller staff occupationally exposed to less radiation to the temple in cardiac procedures, but risk higher doses during vascular cases. Scientific Reports, 10(1), Article number: 16103.

[img]
Preview
Published Version (PDF 1MB)
s41598-020-73101-4.
Available under License Creative Commons Attribution 4.0.

Open access copy at publisher website

Description

This study aimed to evaluate the effect of nurse and doctor height on occupational dose to the temple during fluoroscopically guided cardiovascular procedures. Additionally, an evaluation of the relationship between doctor height and table height was performed. Staff exposed during fluoroscopic procedures may be at elevated risk of cardiovascular damage or oncogenesis and have demonstrated a higher incidence of subscapular cataracts. The heads of taller staff may be exposed to reduced levels of radiation due to the increased distance from the area of highest intensity X-ray scatter. Limited research has been performed investigating height as a predictor of head dose to nursing staff. The level of radiation dose at the level of the temple to the doctor (n = 25), scrub (n = 28), and scout nurse (n = 29) was measured in a prospective single-center, observational study using Philips DoseAware badges. Procedural characteristics were recorded for vascular and cardiac cases performed in three dedicated angiography suites. Data were also collected to investigate relationships between doctor height and table height. Data were collected for 1585 cardiac and 294 vascular procedures. Staff height was a statistically significant predictor of temple dose for doctors, scrub, and scout nurses when considering the full data sample. The log temple dose demonstrated an inverse relationship to staff height during cardiac procedures, but a positive relationship for scrub and scout nurses during vascular studies. This observational study has demonstrated that taller staff are exposed to less cranial exposure dose during fluoroscopically guided cardiac examinations but has revealed a positive correlation between height and temple dose during vascular procedures. It was also determined that doctor height was correlated with average procedural table height and that vascular access point influences the choice of table elevation.

Impact and interest:

2 citations in Scopus
3 citations in Web of Science®
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

78 since deposited on 22 Sep 2020
11 in the past twelve months

Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 204713
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Fontanarosa, Davideorcid.org/0000-0001-6986-3718
Li, Danorcid.org/0000-0002-8647-5917
Drovandi, Chrisorcid.org/0000-0001-9222-8763
Trapp, Jamieorcid.org/0000-0001-5254-0728
Measurements or Duration: 11 pages
DOI: 10.1038/s41598-020-73101-4
ISSN: 2045-2322
Pure ID: 68439990
Divisions: Current > Research Centres > Centre for Data Science
Current > Research Centres > Centre for Biomedical Technologies
Past > Institutes > Institute of Health and Biomedical Innovation
Past > QUT Faculties & Divisions > Science & Engineering Faculty
?? 3232 ??
Current > QUT Faculties and Divisions > Faculty of Science
Current > Schools > School of Chemistry & Physics
Current > QUT Faculties and Divisions > Faculty of Engineering
Copyright Owner: Consult author(s) regarding copyright matters
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au
Deposited On: 22 Sep 2020 02:42
Last Modified: 30 Aug 2025 21:40