Air pollutants associated with smoking in indoor/outdoor of waterpipe cafés in Tehran, Iran: Concentrations, affecting factors and health risk assessment

Masjedi, Mohammad Reza, Taghizadeh, Farhad, Hamzehali, Sanaz, Ghaffari, Sonia, Fazlzadeh, Mehdi, Jafari, Ahmad Jonidi, , Mehrizi, Ehsan Abouee, Moradi, Masoud, Pasalari, Hasan, & Arfaeinia, Hossein (2019) Air pollutants associated with smoking in indoor/outdoor of waterpipe cafés in Tehran, Iran: Concentrations, affecting factors and health risk assessment. Scientific Reports, 9, Article number: 3110.

[img]
Preview
Published Version (PDF 1MB)
75390885.
Available under License Creative Commons Attribution 4.0.

Open access copy at publisher website

Description

<p> Despite increasingly growth in waterpipe smoking in Tehran, so far no study has been conducted on the air quality of the waterpipe and cigarette cafés. Thirty-six cafés were selected and the concentration of three pollutants including formaldehyde, carbon monoxide and nicotine were measured in both indoor and outdoor air of cafés two times (week-day and weekend’s session). Air sampling was performed for 180 min for each pollutant. It was observed that the concentration of pollutants inside the cafés was higher during weekend session (with a higher number of “active waterpipe heads”) compared with findings during the week-day sessions. Furthermore, the concentration of pollutants in the indoor air of the cafés was significantly higher than that of the outdoors (p < 0.05). According to path analysis, the number of “active waterpipe heads” had the maximum impact on generation of pollutants inside the cafés, followed by the type of tobacco as the second influential factor. The average of lifetime cancer risk (LTCR) resulted by formaldehyde exposure through inhalation in waterpipe (WS), cigarette (CS), waterpipe and cigarette (WCS) and none-smoking (NS) cafés in week-day and weekend sessions were estimated to be 111 × 10 <sup>−5</sup> and 61.2 × 10 <sup>−5</sup> , 33.7 × 10 <sup>−5</sup> and 39.4 × 10 <sup>−5</sup> , 271 × 10 <sup>−5</sup> and 322 × 10 <sup>−5</sup> , and 4.80 × 10 <sup>−5</sup> and 5.90 × 10 <sup>−5</sup> , respectively, which exceed the limit value by the U.S.EPA and WHO. The concentration of pollutants in the indoor air of smoking cafés in Tehran is significantly high, such that it can pose serious risks for the health of both personnel and customers. Therefore, decision makers are expected to enact applicable and strict policies so as to abate this public health risk. </p>

Impact and interest:

42 citations in Scopus
33 citations in Web of Science®
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

63 since deposited on 17 Feb 2021
18 in the past twelve months

Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 208091
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Niazi, Sadeghorcid.org/0000-0001-8150-2106
Additional Information: Funding Information: This research work was financial supported by Tobacco Control Research Center (TCRC) (Grant No. TCRC/ IATA1396-10), we gratefully acknowledge them. The authors are also grateful for the technical support from laboratory of environmental health engineering in Iran University of Medical Sciences. We would also like to thank Dr. Alireza Badrizadeh for the sampling.
Measurements or Duration: 11 pages
DOI: 10.1038/s41598-019-39684-3
ISSN: 2045-2322
Pure ID: 75390885
Divisions: Past > Institutes > Institute of Health and Biomedical Innovation
Funding Information: This research work was financial supported by Tobacco Control Research Center (TCRC) (Grant No. TCRC/ IATA1396-10), we gratefully acknowledge them. The authors are also grateful for the technical support from laboratory of environmental health engineering in Iran University of Medical Sciences. We would also like to thank Dr. Alireza Badrizadeh for the sampling.
Copyright Owner: 2019, The Author(s).
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au
Deposited On: 17 Feb 2021 07:17
Last Modified: 29 Jul 2024 18:20