Influence of restrainer bar chairs on the compression and flexural behaviour of reinforced masonry walls

, , Thamboo, Julian A., Noor-E-Khuda, Sarkar, & (2022) Influence of restrainer bar chairs on the compression and flexural behaviour of reinforced masonry walls. Structures, 35, pp. 360-372.

View at publisher

Description

Lateral restrainers are traditionally provided in reinforced masonry (RM) walls to prevent the vertical steel bars from buckling. In the current version of the Australian Masonry Standards (AS 3700–2018), the use of lateral restrainers in RM walls is relaxed, if the vertical rebars are surrounded by grout annulus of twice the diameter of the bars. However, it is challenging to maintain the verticality of the reinforcing bars in the block cores to satisfy the grout annulus requirement without lateral restrainers. To address this challenge, restrainer bar chairs can be used in the construction of RM walls which are easier to employ in comparison to lateral restrainer ties. However, the implications of adopting restrainer bar chairs as an alternative to restrainer ties in RM wall construction are not well verified. In this study, the influence of restrainer bar chairs and conventional lateral ties restraining methods on the axial compression and out-of-plane bending characteristics of RM walls have been investigated. In total, twelve RM walls of dimensions 1390 mm height × 590 mm length × 190 mm thickness were constructed and tested, of which, four walls each were tested under concentric and eccentric compression and four-point bending. The experimental results revealed that the performance of RM walls with restrainer bar chairs and conventional lateral ties were similar, in terms of the observed failure modes, strength, load–displacement characteristics obtained under both compression and out-of-plane loading conditions. Strain measurements on rebars indicated that a composite action was ensued in both restrainer configurations. The capacities of the RM walls under compression and out-of-plane bending were also verified with three different masonry standards provisions and were found adequate with reasonable safety. Overall, it can be concluded that the restrainer bar chairs can effectively be used in RM walls to enable quick and accurate vertical positioning of the rebars and ensure adequate grout annulus around them.

Impact and interest:

7 citations in Scopus
2 citations in Web of Science®
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

Full-text downloads:

71 since deposited on 24 Nov 2021
53 in the past twelve months

Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.

ID Code: 226420
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Zahra, Tatheerorcid.org/0000-0003-1930-5704
Asad, Mohammadorcid.org/0000-0002-4306-7198
Derakhshan, Hosseinorcid.org/0000-0003-1859-4700
Additional Information: Acknowledgement: The authors would like to acknowledge the financial contribution and materials provided by BlockAid Pty Ltd for conducting the tests. The technical support from QUT lab staff is also acknowledged.
Measurements or Duration: 13 pages
DOI: 10.1016/j.istruc.2021.11.023
ISSN: 2352-0124
Pure ID: 101863139
Divisions: Current > Research Centres > Centre for Materials Science
Current > QUT Faculties and Divisions > Faculty of Science
Current > QUT Faculties and Divisions > Faculty of Engineering
Current > Schools > School of Civil & Environmental Engineering
Copyright Owner: 2021 Institution of Structural Engineers
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au
Deposited On: 24 Nov 2021 03:48
Last Modified: 27 Mar 2024 20:00