Patient-Customized Theatre Mattress Supports for Spinal Surgery: A Pilot Study Presenting a Novel Engineering Virtual Design and Manufacturing Technique
Little, J. Paige, Green, Daniel, Izatt, Maree T., Moloney, Gregory, & Askin, Geoffrey N. (2022) Patient-Customized Theatre Mattress Supports for Spinal Surgery: A Pilot Study Presenting a Novel Engineering Virtual Design and Manufacturing Technique. Journal of Medical Devices, 16(2), Article number: 025001.
|
Accepted Version
(PDF 2MB)
105247101. Available under License Creative Commons Attribution 4.0. |
Description
Optimal patient positioning for spine surgery is vital for surgical success and the minimization of complications intra-/postoperatively. In patients with complex comorbidities, commercially available surgical positioning equipment is inadequate. To overcome this, a novel method was developed to create custom-fit patient-specific theater mattresses for patients undergoing spine surgery. An innovative digital workflow involving three-dimensional (3D) surface scanning, 3D simulation, and computer-aided design was developed to manufacture customized theater supports with patient-specific requirements. These supports offered the surgeon an enhanced ability to relieve load bearing on prominent anatomical features or where desired, to tailor the support surface to the patient's anatomy for lengthy surgery. The bespoke theater mattress was evaluated by whether the support resulted in a complication-free surgery. Using this new workflow, case examples for two patients with complex comorbidities were described. The spine surgeon and anesthetist reported the patient-specific custom mattresses were fit as per the required design, provided sufficient clearance around anatomical prominences and areas that required to be unloaded, had sufficient clearance for the anesthetic method and cannulation, provided excellent surgical access and stability during surgery, and postoperatively no soft tissue overload over bony prominence and implanted devices. Positive patient outcomes after successful lengthy surgical interventions were associated with these patient-specific, contoured mattress supports. Future projects will seek to utilize this technology for other types of surgeries and intra-operative positioning requirements, and for a broader demographic of patients in both the pediatric and adult setting.
Impact and interest:
Citation counts are sourced monthly from Scopus and Web of Science® citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
Full-text downloads:
Full-text downloads displays the total number of times this work’s files (e.g., a PDF) have been downloaded from QUT ePrints as well as the number of downloads in the previous 365 days. The count includes downloads for all files if a work has more than one.
ID Code: | 227759 | ||||||
---|---|---|---|---|---|---|---|
Item Type: | Contribution to Journal (Journal Article) | ||||||
Refereed: | Yes | ||||||
ORCID iD: |
|
||||||
Additional Information: | Funding Disclosure: This work was supported by Sealy of Australia who provided support in the form of salary for authors [JPL, DG], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. | ||||||
Measurements or Duration: | 8 pages | ||||||
Keywords: | patient specific, theatre supports, spinal deformity surgery, 3D surface scanning, patient customized support, 3D simulation, patient customised mattress | ||||||
DOI: | 10.1115/1.4053604 | ||||||
ISSN: | 1932-619X | ||||||
Pure ID: | 105247101 | ||||||
Divisions: | Current > Research Centres > Centre for Biomedical Technologies Current > QUT Faculties and Divisions > Faculty of Engineering Current > Schools > School of Mechanical, Medical & Process Engineering |
||||||
Copyright Owner: | 2022 ASME | ||||||
Copyright Statement: | This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au | ||||||
Deposited On: | 03 Feb 2022 01:36 | ||||||
Last Modified: | 09 Feb 2025 07:59 |
Export: EndNote | Dublin Core | BibTeX