Combining high-sensitivity cardiac troponin I and cardiac troponin T in the early diagnosis of acute myocardial infarction

van der Linden, Noreen, Wildi, Karin, Twerenbold, Raphael, Pickering, John W., Than, Martin P., , , , Nestelberger, Thomas, Boeddinghaus, Jasper, Badertscher, Patrick, Gimenez, Maria Rubini, Klinkenberg, Lieke JJ, Bekers, Otto, Schoni, Aline, Keller, Dagmar I., Sabti, Zaid, Puelacher, Christian, Cupa, Janosch, Schumacher, Lukas, Kozhuharov, Nikola, Grimm, Karin, Shrestha, Samyut, Flores, Dayana, Freese, Michael, Stelzig, Claudia, Strebel, Ivo, Miro, Oscar, Rentsch, Katharina, Morawiec, Beata, Kawecki, Damian, Kloos, Wanda, Lohrmann, Jens, Richards, A. Mark, Troughton, Richard, Pemberton, Christopher J., Osswald, Stefan, van Dieijen-Visser, Marja P, Mingels, Alma M, Reichlin, Tobias, Meex, Steven J R, & Mueller, Christian (2018) Combining high-sensitivity cardiac troponin I and cardiac troponin T in the early diagnosis of acute myocardial infarction. Circulation, 138(10), pp. 989-999.

Free-to-read version at publisher website

Description

Background:
Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction.

Methods:
The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms.

Results:
Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0–99.9%]; product: NPV 99.4% [95% CI, 98.8–99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2–100%]; NPV validation cohort 99.5% [95% CI, 98.9–99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6–78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7–87.6%]).

Conclusions:
New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction.

Impact and interest:

59 citations in Scopus
47 citations in Web of Science®
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 228015
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Greenslade, Jaimiorcid.org/0000-0002-6970-5573
Parsonage, Willorcid.org/0000-0002-0223-5378
Measurements or Duration: 11 pages
Keywords: combination, diagnosis, Myocardial infarction, troponins
DOI: 10.1161/CIRCULATIONAHA.117.032003
ISSN: 0009-7322
Pure ID: 105591545
Divisions: Past > Institutes > Institute of Health and Biomedical Innovation
Copyright Owner: 2018 American Heart Association, Inc.
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au