<p>Background: Intradialytic hypotension (IDH) is one of the most common complications associated with haemodialysis (HD), yet the frequency of patient assessment by nurses varies in practice. We sought to measure the frequency of nursing assessments before, during and after HD and to identify any predictors of IDH. Objectives: To audit the frequency, nursing management and contributing factors of IDH. Design: A prospective clinical audit was undertaken over 4 weeks. Participants: Nurses completed audit sheets on 132 patients at three chronic HD units. Measurements: The audit tool consisted of 34 questions related to demographics, HD prescription, frequency of monitoring and nursing interventions. Results: A total of 1584 sessions were performed with 876 (55.3%) audits returned, of which 452 were useable. There were 74 actual episodes of IDH, and a further 72 potential episodes may have been prevented due to nursing intervention. Most nurses reported assessing patients before starting HD and as required before an actual or potential IDH event (n = 85; 63%); few hourly assessments were performed. Predictors of IDH were systolic blood pressure ≤140 mmHg, having more than four comorbidities, dialysate temperature > 36°C, calcium < 1.3 mmol/L and a shorter dialysis session (3.0–4.5 h). These predictors explained 14.1% of the variance in hypotensive episodes during HD. Conclusion: This clinical audit highlighted the importance of assessing blood pressure trends during HD to preemptively intervene before IDH developing. The audit has resulted in a practice change to hourly assessments. Follow-up audits of practice should occur.</p>

Impact and interest:

3 citations in Scopus
3 citations in Web of Science®
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 230891
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Bonner, Annorcid.org/0000-0001-9920-6743
Measurements or Duration: 7 pages
Keywords: haemodialysis, intradialytic hypotension, monitoring
DOI: 10.1111/jorc.12343
ISSN: 1755-6678
Pure ID: 110129592
Divisions: Current > QUT Faculties and Divisions > Faculty of Health
Current > Schools > School of Nursing
Copyright Owner: 2020 European Dialysis and Transplant Nurses Association/European Renal Care Association
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au
Deposited On: 18 May 2022 01:03
Last Modified: 29 Feb 2024 12:22