Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis
Homes, Ryan, Clark, Devon, Moridzadeh, Sina, Tosovic, Danijel, Van den Hoorn, Wolbert, Tucker, Kylie, & Midwinter, Mark (2023) Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis. Sensors, 23(1), Article number: 537.
Open access copy at publisher website
Description
Examination of gait patterns has been used to determine severity, intervention triage and prognostic measures for many health conditions. Methods that generate detailed gait data for clinical use are typically logistically constrained to a formal gait laboratory setting. This has led to an interest in portable analysis systems for near clinical or community-based assessments. The following study assessed with the wearable accelerometer/gyroscopic, gait analysis system (LEGSYS+TM) and the standard of static motion capture camera (MOCAP) analysis during a treadmill walk at three different walking speeds in healthy participants (n = 15). To compare each speed, 20 strides were selected from the MOCAP data and compared with the LEGSYS+ strides at the same time point. Both scatter and bland-Altman plots with accompanying linear regression analysis for each of the parameters. Each stride parameter showed minimal or a consistent difference between the LEGSYS+ and MOCAP, with the phase parameters showing inconsistencies between the systems. Overall, LEGSYS+ stride parameters can be used in the clinical setting, with the utility of phase parameters needing to be taken with caution.
Impact and interest:
Citation counts are sourced monthly from Scopus and Web of Science® citation databases.
These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.
Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.
| ID Code: | 240708 | ||
|---|---|---|---|
| Item Type: | Contribution to Journal (Journal Article) | ||
| Refereed: | Yes | ||
| ORCID iD: |
|
||
| Measurements or Duration: | 14 pages | ||
| Keywords: | gait, LEGSYS+, motion capture, phase parameters, walking | ||
| DOI: | 10.3390/s23010537 | ||
| ISSN: | 1424-8220 | ||
| Pure ID: | 137826086 | ||
| Copyright Owner: | 2023 The Authors | ||
| Copyright Statement: | This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au | ||
| Deposited On: | 21 Jun 2023 16:01 | ||
| Last Modified: | 07 Feb 2026 06:24 |