Comparison of range of motion between 2-year clinical outcomes and predictions of a static scapula preoperative planning software for reverse shoulder arthroplasty

, Ingoe, Helen, Salhi, Asma, Italia, Kristine, Gilliland, Luke, , Pareyon, Roberto, , , , , & (2024) Comparison of range of motion between 2-year clinical outcomes and predictions of a static scapula preoperative planning software for reverse shoulder arthroplasty. Seminars in Arthroplasty JSES.

Open access copy at publisher website

Description

<p>Background: Preoperative planning has gained popularity in the management of reverse shoulder arthroplasty (RSA). Commercially available software provides 3-dimensional segmentation of scapula and humerus, as well as providing arc of motion for the implanted articulation and identifying potential areas of bony impingement. However, these software algorithms use a fixed scapula model, disregarding the preoperative clinical range of motion (C-ROM) of the patient, be it glenohumeral or scapulothoracic, as well as any soft tissue parameters. This study aims to compare the ROM based on preoperative planning software by using the implant position from postoperative computed tomography (CT) images (predicted ROM using preoperative planning software [P-ROM]), with the C-ROM assessed at minimum of 2 years of follow-up. Methods: Preoperative and postoperative CT scans of 46 patients who underwent primary RSA between 2017 and 2021 were analyzed. At the postoperative 2-year review, each patient was assessed for active ROM. Implant size and position based on operative notes and postoperative CT scans were used to replicate the performed surgery in the planning software. Abduction, flexion, and external rotation motion were simulated and recorded. The relationship between C-ROM and P-ROM was investigated using linear regression analysis, Pearson correlation coefficient, and paired t-test. Results: P-ROM was significantly lower than C-ROM at 2 years postoperatively (P < .001), with an average discrepancy of 78° in abduction, 47° in flexion, and 37° in external rotation (C-ROM: abduction 155° ± 21° [80°-180°]; flexion 160° ± 17° [90°-180°]; external rotation 52° ± 14° [10°-80°] vs. P-ROM: abduction 77° ± 13° [53°-107°]; flexion 112° ± 25° [67°-180°]; external rotation 15° ± 21° [0°-79°]). The linear regression analysis indicated weak agreement between C-ROM and P-ROM (abduction R<sup>2</sup> = 0.03; flexion R<sup>2</sup> = 0.01; external rotation R<sup>2</sup> = 0.04). Pearson's correlation coefficients revealed weak correlations of −0.18, 0.03, and 0.21 for abduction, flexion, and external rotation, respectively. Conclusion: P-ROM based on preoperative software in its current form does not allow the prediction of the C-ROM at 2 years of follow-up for patients undergoing RSA.</p>

Impact and interest:

0 citations in Scopus
Search Google Scholar™

Citation counts are sourced monthly from Scopus and Web of Science® citation databases.

These databases contain citations from different subsets of available publications and different time periods and thus the citation count from each is usually different. Some works are not in either database and no count is displayed. Scopus includes citations from articles published in 1996 onwards, and Web of Science® generally from 1980 onwards.

Citations counts from the Google Scholar™ indexing service can be viewed at the linked Google Scholar™ search.

ID Code: 250897
Item Type: Contribution to Journal (Journal Article)
Refereed: Yes
ORCID iD:
Pivonka, Peterorcid.org/0000-0001-9183-530X
Measurements or Duration: 9 pages
Keywords: Computed tomography, Level IV, Planning software, Preoperative planning, Range of motion prediction, Retrospective Case Series, Reverse shoulder arthroplasty, Scapula model
DOI: 10.1053/j.sart.2024.05.001
ISSN: 1045-4527
Pure ID: 173682576
Divisions: Current > QUT Faculties and Divisions > Faculty of Engineering
Current > Schools > School of Mechanical, Medical & Process Engineering
Funding Information: P.P., K.C., and A.G. would like to gratefully acknowledge funding received from the Australian Research Council (ARC) Industrial Transformation Training Centre for Joint Biomechanics (IC190100020).
Funding:
Copyright Owner: 2024 The Author(s)
Copyright Statement: This work is covered by copyright. Unless the document is being made available under a Creative Commons Licence, you must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a Creative Commons License (or other specified license) then refer to the Licence for details of permitted re-use. It is a condition of access that users recognise and abide by the legal requirements associated with these rights. If you believe that this work infringes copyright please provide details by email to qut.copyright@qut.edu.au